Connect your station equipment and operations in one system
From dispenser and tank readings to sales, alerts, reports and multi-site management.
Automation is neither software alone nor a device alone: Obour Al Shaheen supplies the hardware; SUNDUS provides software, data and operations.
Four modules, each feature with its status
SUNDUS is in development and not yet in production. We show the status as it is.
Daily station operations
Shifts, sales, products, expenses and the operations log for the site team.
Operational financial control
Revenue, cash, card, cost, reconciliation and profitability per site and across sites — an operational and analytical layer, not a statutory ledger.
Station device connectivity
Collects dispenser, tank and device data through the controller and integration layer — read-only.
Fuel delivery management
From fuel order to closing the delivery: tank reading before and after unloading, quantity matching and recording the difference.
Show all capabilities
- Shifts and business dayPilot
- Meter readings and shift closePilot
- Site team appIn development
- Expenses, suppliers and credit accountsOn the roadmap
- Inventory, invoices and site settlementsOn the roadmap
- Weighted-average fuel cost, VAT and period closeIn development
- Revenue, cash and paymentsOn the roadmap
- Receivables, suppliers and expensesOn the roadmap
- Reconciliation, variances and profitabilityOn the roadmap
- Integration with ERP and e-invoicingOn the roadmap
- Raw tank readings: level, water, temperaturePilot
- Dispenser sales captured exactly oncePilot
- Device registry and controller identityPilot
- Offline devices and alertsOn the roadmap
- Additional controllers and gaugesNeeds a compatibility check
- Delivery flow from order to closeIn development
- Matching delivered quantity with the stock changeOn the roadmap
- Recording and following up differencesOn the roadmap
From the device to SUNDUS
The actual wiring is designed per project, by equipment and compatibility.
The fuel delivery journey
Matching the delivered quantity with the stock change and operating data. In development
- 1Fuel order
- 2Supplier order
- 3Tanker arrival
- 4Tank reading before
- 5Unloading
- 6Tank reading after
- 7Reconciliation
- 8Record the difference
- 9Close
An operator's day
One station or a whole network: each user sees only what belongs to their role and sites.
- MorningOpens every station: sales and tank levelsPilot
- During the daySees offline devices and alertsOn the roadmap
- A delivery arrivesDelivery flow: before and after unloadingIn development
- A difference appearsLogged as an exception to follow upOn the roadmap
- A problem appearsBecomes a maintenance taskOn the roadmap
- End of dayOperational and financial summary per siteIn development
The multi-site view has been tested with demo data only.

Readiness for fuel station automation requirements
From the Ministry of Energy "Facility qualification standards for managing, operating and maintaining fuel stations and service centres" — operation and maintenance table. Not a ministry approval.
| Item | Requirement | Type | What we offer today |
|---|---|---|---|
| 15 | A central electronic link (forecourt controller) taking pump readings and allowing instant remote price changes | Mandatory | We supply compatible controllers. Sales reading in SUNDUS is in pilot; price management from SUNDUS is not available today. Pilot |
| 16 | An inventory management system | Mandatory | Raw tank readings in pilot; inventory in litres in development. In development |
| 17 | An automatic tank reading system | Flexible | We supply ATG systems and probes to order. Pilot |
| 18 | A transportation management system | Flexible | SUNDUS Delivery is in development. In development |
A regulatory requirement with no confirmed public interface.
An actual, tested official API or platform.
Documents, certificates and dates — not an automated link.
Future readiness once an official interface exists.
- Ministry of Energy — Readiness for central-link requirements until an official integration exists and is tested.Required architecture
- E-invoicing (ZATCA) — SUNDUS does not issue tax invoices; integration goes through the business’s approved invoicing system or ERP.On the roadmap
- Pump metrology and verification — Keeping model-approval and verification certificates, expiry dates and reminders.Compliance
This section summarises the reference and does not replace the official text or the project engineer. Last reviewed: November 2026.
Hardware we supply for your station
We pick models after reviewing your dispensers and tanks. SUNDUS compatibility is assessed per project.
Al Shaheen fuel dispensersDispenses and meters fuelReads: Volume and amount totalsCompatibility check
ProGauge MagLink LX Plus® consoleAutomatic tank gauge console (ATG)Reads: Level, water, temperature, alarmsCompatibility check
ProGauge® DMP™ Magnetostrictive Probe(s)A probe inside the tankReads: Fuel level, water, temperatureCompatibility check
Discriminating Sump Sensor (Discriminating Dispenser Pan / STP Sump Sensor)A sensor in the sumpReads: Liquid present; fuel vs waterCompatibility check
Submersible turbine pumpPushes fuel from the tankReads: Run status via the control boxCompatibility checkEach station's data belongs to its owner
- Secure sign-in and role-based permissions
- Separation between customers and sites
- Activity logs
- Backups with rehearsed restore
- Read-only connection to station devices
Request an automation design for your station
Two questions and a mobile number. Dispenser, tank and controller details are collected with you later in the technical review.
- 1. Your request arrives with a number
- 2. A technical review of your equipment
- 3. A proposed design and quote