Loading the station…
Educational model · not a customer site
Text version
Station components
- Canopy & lighting
- Shades the forecourt and lights it at night with 400 W fixtures. Above the pump islands. Canopy lighting 400 W · Air & water tower
- Fuel dispenser
- Meters and sells fuel. The Al Shaheen unit carries six nozzles, three per side (diesel, 91, 95). On the pump island, above the containment sump. Al Shaheen fuel dispensers · Auto nozzle – 91 · Fuel hose
- Price sign
- Displays fuel prices. At the station entrance. Fuel price sign
- Emergency stop
- Cuts power to all dispensers and pumps at once. Visible points at the forecourt and building.
- Tanker unloading
- The tanker discharges into the matching tank. Next to the fill points.
- Station building
- Holds the control room, distribution board and point of sale. Behind the forecourt.
- Underground tanks
- Store fuel; a double wall leaves a monitorable interstitial space. Underground, one per grade. Underground fuel storage tanks · Tank anchoring · Manhole cover 70×70 cm – 50 t
- Tank anchoring
- Straps and a base that stop the tank floating. Under and around the tank. Tank anchoring
- Submersible pump
- Pushes fuel under pressure to every dispenser on that grade. Inside the tank; head in the tank sump. Submersible turbine pump · Submersible pump control box · ProGauge Electronic Pressurized Line Leak Detection (PLLD)
- Tank sump & cover
- Contains leaks from fittings and gives service access. On the tank, cover at grade. Containment sumps · Entry boots · Manhole cover 70×70 cm – 50 t
- Tank probe
- Measures fuel level, water level and temperature. Inside the tank, vertical. ProGauge® DMP™ Magnetostrictive Probe(s) · ProGauge® DMP Flex™ Magnetostrictive Probe(s) · ProGauge™ Density Measurement Float
- Double-wall product piping
- Carry fuel to each dispenser; any leak runs in the outer pipe to the sump. Under the forecourt. Double / single wall fuel pipe · Polyethylene (PE) pipe · Secondary containment coil
- Fittings
- Elbows, tees, couplings, reducers, adapters and flanges — electrofusion or threaded. At every bend and branch. Electrofusion socket / coupler · 2-inch electrofusion elbow · Electrofusion tee
- Entry boots
- Seal pipes and conduits entering sumps. On sump walls. Entry boots · Penetration seals · Test boots
- Flexible connectors
- Absorb movement and settlement between line and equipment. Under the dispenser and at the pump head. Flexible connector
- Shear valve
- Closes the product line if the dispenser is hit or catches fire. Under the dispenser, in the sump. Emergency shear valve
- Under-dispenser sump
- Contains leaks below the dispenser; the shear valve closes the line on impact. Under each dispenser. Containment sumps · Entry boots · Emergency shear valve
- Fill point & spill bucket
- Fuel entry to the tank; the bucket catches drips when the hose is removed. Above each tank. Fill / drop adaptor with cap · Fill caps · Spill containers
- Spill container
- Catches drips when the delivery hose is removed. Around the fill point, at grade. Spill containers
- Fill pipe
- Carries fuel from the adapter into the tank. From the adapter to the tank top. Fill pipe / riser · Threaded couplings · Reducers
- Drop tube
- Takes fuel near the floor to cut vapour and static. Inside the tank. Drop tubes
- Overfill prevention valve
- Stops the delivery before the tank overfills. In the drop tube. Overfill prevention valves
- Stage I vapour recovery
- During delivery, displaced tank vapour returns to the tanker instead of venting. Next to the fill points. Stage I vapour recovery adapters · Vapour adapter caps · Vapour return piping
- Vent pipes & P/V valve
- Let the tank breathe; the valve limits vapour release. Vertical, beside the building. P/V vapor vent · Vent pipes & risers · Vent caps
- Vent lines
- Carry displaced vapour to the vent risers. From the tank tops to the vent risers. Vent pipes & risers · Polyethylene (PE) pipe
- Sump sensors
- Sump sensors: detect liquid; discriminating types tell fuel from water. In dispenser sumps and tank sumps. Discriminating Sump Sensor (Discriminating Dispenser Pan / STP Sump Sensor) · Non-Discriminating Dual-Float Sump Sensor · Single Level Sump Sensor – Float Switch – Large
- Interstitial sensor
- Detects liquid reaching the space between the walls. Between the tank walls. Interstitial Level Sensor – Small · Discriminating Interstitial Sensor - Optical · Discriminating Interstitial Sensor
- Vapour sensor
- Detects hydrocarbon vapour in the soil around the tank. In the dry observation well. Hydrocarbon Vapor Sensor · Discriminating Monitoring Well Sensor
- Observation well
- Allows checks for fuel or vapour in the soil. In the tank backfill. Observation well · Discriminating Monitoring Well Sensor
- Pressurised line leak detection (PLLD)
- Monitors line pressure, runs leak tests and alarms on pressure decay. On the submersible pump head. ProGauge Electronic Pressurized Line Leak Detection (PLLD) · PLLD Sensor · PLLD DAS
- Nozzles & hoses
- Where the customer fuels. The nozzle shuts off automatically when the tank is full. On the dispenser tower. Auto nozzle – 91 · Fuel hose · Safety breakaway coupling
- Forecourt controller
- Brings together communication between forecourt devices and central systems, as the project design requires. In the control-room rack. Forecourt controller
- Tank gauge console (ATG)
- Reads tank probes and leak sensors and raises alarms. In the control room. ProGauge MagLink LX Plus® console · ProGauge MagLink LX Ultimate® console · Automatic tank gauging system
- Integration layer
- Carries device data to the platform securely, as the project design requires. In the control room.
- SUNDUS platform
- Shows sales and tanks for all of an owner’s stations in one place. Cloud; opened from phone or desktop. Forecourt controller · Automatic tank gauging system
- Pressure testing
- Pressure-test lines after installation. On site, before backfill. Pressure test kits · Test plugs · Test boots
- Electrofusion tools
- Prepare and fuse: cut, scrape, clamp, fuse. On site. Electrofusion control units · Pipe scrapers · Pipe cutters
- Measurement & calibration
- Check dispenser accuracy with a prover can. At the dispenser. Volumetric prover can · Digital flow meter · Water & fuel gauging paste